Active Power Filter (APF)

Update:2017/6/20      Click:

Multiplexing and multi - level PWM technique
Unit capacity up to 3000A

       Most of the loads that are widely used are nonlinear loads, such as rectifier, frequency converter, UPS, elevator, air conditioner, energy saving lamp, duplicator, domestic appliance, etc.. Such nonlinear loads will produce a large amount of harmonic current and input them to the power network, bringing in the distortion of voltage waveform and causing serious damages to the power network and all the back-end users. In addition, the impact and fluctuating loads, such as: electric-arc furnace, welding equipment, etc., will not only produce a large amount of higher harmonics , but also cause the quality problems of electric energy such as voltage fluctuation, flickering, and three-phase imbalance, seriously influencing the usage efficiency of electric energy.
         AP series of active power filters (APF) can dynamically filter out harmonics for 2-50 times in real time, with a valid filtering rate up to 95%, to rapidly dispose of flickering and voltage fluctuation, and possess strong expansion capability. The filters with different capacities can expand mutually, allowing the user to make more flexible harmonic treatment schemes.

ØFeatures

 

ØApplication fields

1.200V, 400V, 600V and 750V, rated capacity of single device up to 3000A;
2.The failed module imposes no impacts on the operation of normal module, available for live replacement and gives high reliability for the whole system;
3.Ability to dynamically filter out harmonics for 2-50 times in real time, with a valid filtering rate up to 95%;
4.The total response time is less than 10ms;
5. Better treatment on voltage fluctuation and flickering;
6. Unique ripple self-elimination technique;
7. High stability and reliability, and the design life is 20 years.
 
1.The power systems in the areas where there are larger power network harmonics, such as the plant, enterprise, etc.
2.The production enterprises using the high-power nonlinear loads and impact loads (such as the air pumps).
3.The power systems with higher requirements on the quality of power network, such as the hospital.
4.Power system in need of comprehensive compensation against reactive power, harmonic and three-phase imbalance.
5.laces of original equipment transformation or the places where the device is required to be installed with switch cabinet in combined cabinets.

 